Expert calibration lab in
Châtellerault – France

Opening hours

Mon
08:00 - 17:00
Tue
08:00 - 17:00
Wed
08:00 - 17:00
Thu
08:00 - 17:00
Fri
08:00 - 17:00
Contact
+33 (0)5 49 90 08 61
ZI de la Naurais Bachaud
86530 NAINTRÉ

ACCREDITATIONS

CAPABILITIES

Accredited Capabilities
Traceable Capabilities
Temperature
Radiometry / Photometry
Liquid flow
Gas flow
Electricity
Chemical
Accelerometry
Dimensional
Force
Hardness
Mass / Scale
Pressure / Vacuum
Torque
Temperature

Temperature

Non-accredited Capabilities

Global Calibration Scope

  • Range: -196°C up to 1550°C
  • Fixed points: TP Ar, TP Mercury, TP Water, Melting point of Galium, FP Indium, FP Tin, FP Zinc, FP Al, FP Ag…

Common equipment serviced: temperature measurers, Generators/calibrators, Chillers, Thermistors, Infrared radiation sources, Temperature Controllers, Temperature Indicators

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Radiometry / Photometry

Radiometry / Photometry

Non-accredited Capabilities

Global Calibration Scope

  • Illuminance: 0.5 to 20 000 lux
  • Luminance: 0.2 to 15 000 ㏅/m2…

Common equipment serviced: Illuminance meter, Luminance meter, Spectrophotometer, Glossmeter, Photometer, Colorimeter, Pyranometer, Irradiance meter

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Liquid flow

Liquid flow

Non-accredited Capabilities

Global Calibration Scope: Liquid flow (water): 0.12 l/h to 120 m3/h; Liquid flow (Hydrocarbon oils (Kerosene, Gas oil, Shell Tellus 32, Shell Tellus 100)): 0.6 l/min to 3000 l/min

Common equipment serviced: Liquid flow meter, Backflow gages, Flow analyzers, Gas flow meters, Flow transducers, Flow transmitters, Leak testers, Orifices, Rotameters, Turbine meters

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Gas flow

Gas flow

Non-accredited Capabilities

Global Calibration Scope: Gas flow (air): 0.5 ml/min to 4000 m3/h (the range is lower depending on gas used (nitrogen, argon or any inert gases)

Common equipment serviced: Anemometers (thermal & vane), Bubble flowmeters, Gas flow meters, Gas meters, Thermal mass flow controllers, Variable area flow meters, Backflow gages, Flow analyzers, Gas flow meters, Flow transducers, Flow transmitters, Leak testers, Orifices, Rotameters, Turbine meters

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Electricity

Electricity

Non-accredited Capabilities

Global Calibration Scope

  • AC Power & Energy: Triphasic active & Active Monophasic f = 50 – 60 Hz, 0,7 W ≤ P ≤ 71 MW, (Wattmeters, Energy analyzers, Power analyzers, Watt-hour meters, Power converters, multifunction calibrators, Sources for meter or relay testing
  • High voltage:
    • DC: 1 kV to 200 kV
    • AC (50 Hz): 1 kV to 175 kV
  • Magnetometers: 0 to 1700 mT…

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Chemical

Chemical

Non-accredited Capabilities

Global Calibration Scope

  • Viscosity: kinematic and dynamic, consistometric cup, etc.
  • Conductivity: Electrical (0 μS/cm to 200 mS/cm) and with Certified Reference Material (1,1 μS/cm to 111,3 mS/cm)
  • Gas detector and Gas Concentration : Carbon monoxide, Nitrogen monoxide, Nitrogen dioxide, Oxygen, Total gaseous organic carbon, Dilution apparatus for olfactometry, Sulfur dioxide, Carbon dioxide, Hydrogen sulfide, Benzene, Methane, Ozone, Propane, etc.
  • Refractometry: (1.33 ~ 1.62) nD (refractive index), 0 to 87.6% Brix, etc.

Common equipment serviced: Conductivity meters, Salinity meters, pH meters, Sucrose solutions, Gas detectors and gas concentration, Particle counters, Refractometry instruments, Viscosity instruments

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Accelerometry

Accelerometry

Non-accredited Capabilities

Global Calibration Scope

  • Shock: between 20g and 5,000g (subject to device weight and voltage output)
  • Accelerometer: 0.1 m/s² to 750 m/s² (0.4 Hz to 10 kHz…)

Common equipment serviced: Integrated piezoelectric electronics, Piezoelectric accelerometers, Piezoresistive accelerometers, Charge amplifiers and systems

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Dimensional

Dimensional

Accredited Capabilities

Dimensionnel cotes fixes et cotes variables
Cote fixe : jusqu’à 1 000 mm
Cote variable : jusqu’à 2 000 mm
Projecteur de profil / mesureur optique
Marbres / Colonnes de mesures
Bras de mesures poly articulés

Mesures 3D / 2D Optique
3D : 700 x 450 x 400 mm
2D : 200 x 300 mm

Interférométrie
Accrédité COFRAC jusqu’à 1 000 mm (sur site et en laboratoire)

Force

Force

Non-accredited Capabilities

Dynamomètres jusqu’à 5000 N

 

Hardness

Hardness

Non-accredited Capabilities

Duromètres Shore A et D
Machines de dureté fixes et portables HR/HB/HV

Mass / Scale

Mass / Scale

Non-accredited Capabilities

Balances de pesée de 1 mg à 180 kg

Pressure / Vacuum

Pressure / Vacuum

Non-accredited Capabilities

Étendue : de -0,95 à 70 bar en air, pression relative

Étendue : de 0 à 1 000 bar en eau, pression relative

Torque

Torque

Non-accredited Capabilities

Clés dynamométriques jusqu’à 1 000 N.m
Visseuses jusqu’à 60 N.m

 

Temperature
Radiometry / Photometry
Liquid flow
Gas flow
Electricity
Chemical
Accelerometry
Dimensional

Dimensionnel cotes fixes et cotes variables
Cote fixe : jusqu’à 1 000 mm
Cote variable : jusqu’à 2 000 mm
Projecteur de profil / mesureur optique
Marbres / Colonnes de mesures
Bras de mesures poly articulés

Mesures 3D / 2D Optique
3D : 700 x 450 x 400 mm
2D : 200 x 300 mm

Interférométrie
Accrédité COFRAC jusqu’à 1 000 mm (sur site et en laboratoire)

Force

Dynamomètres jusqu’à 5000 N

 

Hardness

Duromètres Shore A et D
Machines de dureté fixes et portables HR/HB/HV

Mass / Scale

Balances de pesée de 1 mg à 180 kg

Pressure / Vacuum

Étendue : de -0,95 à 70 bar en air, pression relative

Étendue : de 0 à 1 000 bar en eau, pression relative

Torque

Clés dynamométriques jusqu’à 1 000 N.m
Visseuses jusqu’à 60 N.m

 

Réparations mécaniques

Laboratory tour

Our laboratories provides instrument calibration and repair services that are accredited and/or certified in accordance with ISO/IEC 17025. Instrument calibration and repair services can be delivered at your site or at our lab.