Expert calibration lab in
Great Yarmouth – United Kingdom
Opening hours
Faraday Road
Great Yarmouth
Norfolk
NR31 0NF


UKAS Accreditation

ISO 17025
CAPABILITIES
Volume
Global Calibration Scope
- Volumetric Instruments (Beakers, Volumetric Containers…): up to 20 000 mL
- Pipette: 0.1µL up to 1 000 mL
- Syringe: up to 200 mL
Common equipment serviced: Burettes, Flask, Syringe, Pipettes, Test tubes, Beakers, Dispenser, Tanks, Vessels, Gauge overflow, Gauge windows, Concrete air content meters, Level probes Pycnometers, Titrators
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Chemical
Global Calibration Scope
- Viscosity: kinematic and dynamic, consistometric cup, etc.
- Conductivity: Electrical (0 μS/cm to 200 mS/cm) and with Certified Reference Material (1,1 μS/cm to 111,3 mS/cm)
- Gas detector and Gas Concentration : Carbon monoxide, Nitrogen monoxide, Nitrogen dioxide, Oxygen, Total gaseous organic carbon, Dilution apparatus for olfactometry, Sulfur dioxide, Carbon dioxide, Hydrogen sulfide, Benzene, Methane, Ozone, Propane, etc.
- Refractometry: (1.33 ~ 1.62) nD (refractive index), 0 to 87.6% Brix, etc.
Common equipment serviced: Conductivity meters, Salinity meters, pH meters, Sucrose solutions, Gas detectors and gas concentration, Particle counters, Refractometry instruments, Viscosity instruments
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Gas flow
UK Calibration Scope:
- Gas flow (air): 5 ml/min to 1000 L/min (the range is lower depending on gas used nitrogen, argon or any inert gases)
Common equipment serviced: Anemometers (thermal & vane), Bubble flowmeters, Gas flow meters, Gas meters, Thermal mass flow controllers, Variable area flow meters, Backflow gages, Flow analyzers, Gas flow meters, Flow transducers, Flow transmitters, Leak testers, Orifices, Rotameters, Turbine meters
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Liquid flow
UK Calibration Scope:
- Liquid flow (water): Volume: 0.6 l/m to600 l/mMass flow: 0.6kg/min to 600kg/min (Gravimetric method)
- Liquid flow (Hydrocarbon oils (Kerosene, Gas oil, Shell Tellus 32, Shell Tellus 100)): Volume: 0.6 l/m to 3000 l/m Mass flow: 0.6kg/min to 2400kg/min (Gravimetric method)
- Liquid Density: 688 kg/m3 to 1000kg/m3
Common equipment serviced: Liquid flow meter, Backflow gages, Flow analyzers, Gas flow meters, Flow transducers, Flow transmitters, Leak testers, Orifices, Rotameters, Turbine meters
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Pressure / Vacuum
UK Calibration Scope
- Gas pressure (gauge, absolute and differential): up to 10.1 MPa
- Hydraulic pressure (gauge and absolute): up to 500 MPa
Common equipment serviced: Manometers, Pressure calibrators, Sensor transmitters, Vacuum, Safety devices, Pressure balance
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
UK Calibration Scope:
- Gas flow (air): 5 ml/min to 1000 L/min (the range is lower depending on gas used nitrogen, argon or any inert gases)
Common equipment serviced: Anemometers (thermal & vane), Bubble flowmeters, Gas flow meters, Gas meters, Thermal mass flow controllers, Variable area flow meters, Backflow gages, Flow analyzers, Gas flow meters, Flow transducers, Flow transmitters, Leak testers, Orifices, Rotameters, Turbine meters
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
UK Calibration Scope:
- Liquid flow (water): Volume: 0.6 l/m to600 l/mMass flow: 0.6kg/min to 600kg/min (Gravimetric method)
- Liquid flow (Hydrocarbon oils (Kerosene, Gas oil, Shell Tellus 32, Shell Tellus 100)): Volume: 0.6 l/m to 3000 l/m Mass flow: 0.6kg/min to 2400kg/min (Gravimetric method)
- Liquid Density: 688 kg/m3 to 1000kg/m3
Common equipment serviced: Liquid flow meter, Backflow gages, Flow analyzers, Gas flow meters, Flow transducers, Flow transmitters, Leak testers, Orifices, Rotameters, Turbine meters
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
UK Calibration Scope
- Gas pressure (gauge, absolute and differential): up to 10.1 MPa
- Hydraulic pressure (gauge and absolute): up to 500 MPa
Common equipment serviced: Manometers, Pressure calibrators, Sensor transmitters, Vacuum, Safety devices, Pressure balance
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.