Expert calibration lab in
Lyon – France
Opening hours
69800 SAINT-PRIEST

CAPABILITIES
Radiometry / Photometry
Global Calibration Scope
- Illuminance: 0.5 to 20 000 lux
- Luminance: 0.2 to 15 000 ㏅/m2…
Common equipment serviced: Illuminance meter, Luminance meter, Spectrophotometer, Glossmeter, Photometer, Colorimeter, Pyranometer, Irradiance meter
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Pressure / Vacuum
Global Calibration Scope
- Vacuum: primary and secondary
- Altimeter: up to 47 000 m
- Pressure gauge: up to 500 MPa
Common equipment serviced: Manometers, Pressure calibrators, Sensor transmitters, Vacuum, Safety devices, Pressure balance
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Liquid flow
Global Calibration Scope: Liquid flow (water): 0.12 l/h to 120 m3/h; Liquid flow (Hydrocarbon oils (Kerosene, Gas oil, Shell Tellus 32, Shell Tellus 100)): 0.6 l/min to 3000 l/min
Common equipment serviced: Liquid flow meter, Backflow gages, Flow analyzers, Gas flow meters, Flow transducers, Flow transmitters, Leak testers, Orifices, Rotameters, Turbine meters
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Gas flow
Global Calibration Scope: Gas flow (air): 0.5 ml/min to 4000 m3/h (the range is lower depending on gas used (nitrogen, argon or any inert gases)
Common equipment serviced: Anemometers (thermal & vane), Bubble flowmeters, Gas flow meters, Gas meters, Thermal mass flow controllers, Variable area flow meters, Backflow gages, Flow analyzers, Gas flow meters, Flow transducers, Flow transmitters, Leak testers, Orifices, Rotameters, Turbine meters
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Torque
Global Calibration Scope
- Torque measuring devices (sensors, transducers, measuring chains…): 0,001 to 5 000 Nm
- Hand torque tools (wrenches, screwdrivers …): 0,02 to 5 000 Nm
- Torque multiplier: 50 to 5 000 Nm
Common equipment serviced: Torque analyzer, Torque sensor, Torque tester, Torquemeter, Torque transducer, Torque multiplier, Torque gun, Torque wrench, Torque screwdriver, Joint simulator, Hydraulic torque wrench
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Force
Global Calibration Scope
- Push pull force measuring devices in tension and compression: up to 1 MN
- Force machine: up to 5 MN (compression) and up to 1 MN (tension)
Common equipment serviced: Dynamometers, Force machines (Tension and/or Compression), Load cell, Force gauges, Strainmeter, Crimping pliers, Charpy testers, Cable tie tools, Press, Retention tools, Wire wrap tools, Spring balance
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Dimensional
Global Calibration Scope
- Gauge block (steel, tungsten carbide, ceramic…): up to 1500 mm
- Long length (standard tape rules, peripheral gauges…): up to 100 m
Common equipment serviced: Angle instruments, Measuring bench/optical, Depth gauge, Gauge blocks, Height gauges, Micrometers, Length instruments, Limit gauges, Form and surface, Thread gauges
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Accelerometry
Global Calibration Scope
- Shock: between 20g and 5,000g (subject to device weight and voltage output)
- Accelerometer: 0.1 m/s² to 750 m/s² (0.4 Hz to 10 kHz…)
Common equipment serviced: Integrated piezoelectric electronics, Piezoelectric accelerometers, Piezoresistive accelerometers, Charge amplifiers and systems
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Chemical
Phmètres, Conductivimètres, Spectrophotomètres, Analyseurs divers, Incubateurs…
Mesures réalisées : pH, Conductivité, Viscosité, Densité, Osmolarité…
Analyseurs divers
Electricity
Multimètres, Alimentations, Pinces, Analyseurs de Puissance, Sondes Haute-Tension…
Tension de 0,5 µV à 60 kV DC et 1 mV à 40 kV AC (prestation accréditée)
Intensité de 2 pA à 1 kA DC et 10 µA à 2 kA AC (prestation accréditée)
Puissance Mono et triphasé cos Entre 0,5 et 1 AR de 1 à 100 kW DC et de 0,75 W à 26 kW AC (prestation accréditée)
Résistance de 100 µΩ à 100 GΩ jusqu’à 1 kV en prestation accréditée et 15 kV en prestation non accréditée
Énergie Mono et triphasé cos Entre 0,5 et 1 AR, de 10 V à 230 V et de 0,1 A à 100 A (10 A en triphasé) (prestation accréditée)
Charge électrique : de 50 pC à 20 nC (prestation accréditée)
Calibrateurs de process en simulation électrique
Et aussi : Capacité, Inductance, Facteur de puissance, Compteur-Fréquencemètre,…
Humidity
Thermo-Hygromètres…
Thermo-Hygromètres : de -70 °C à 180 °C de 5% à 95% HR
Mass / Scale
Masses normalisées ou non-normalisées
Prestations non accréditées : de 1 mg à 20 kg classe M1, M2, M3
Prestations accréditées : de 1 g à 20 kg classe M1, M2, et M3
Classe F2 : nous consulter
Temperature
Thermo-Hygromètres, Pyromètres…
Sondes seules ou chaînes de mesure de mesure : de -80 °C à 1 200 °C (prestation accréditée)
Sondes de surface : 20 °C à 320 °C
Pyromètres : 100 °C à 900 °C
Thermo-Hygromètres : de -70 °C à 180 °C de 5% à 95% HR
Chaîne de température sur site de -80 °C à 1200 °C (Cofrac jusqu’à 600 °C)
Volume
Micropipettes, Pipettes, Burettes…
Mesures réalisées : de 1 µl à 500 ml à partir d’une contenance de 5 µl
Suivant NF EN ISO 8655
Thermal and climatic testing
Enceintes Climatiques et Thermostatiques, Thermocycleurs, Étuves, Fours…
Enceintes climatiques & thermostatiques : de -80 °C à 1200 °C et de 1% à 95% HR
Caractérisation selon normes FDX 15-140 / L06-450
Qualification d’autoclaves : de 0 °C à 140 °C
Thermocycleurs PCR/QPCR
Phmètres, Conductivimètres, Spectrophotomètres, Analyseurs divers, Incubateurs…
Mesures réalisées : pH, Conductivité, Viscosité, Densité, Osmolarité…
Analyseurs divers
Multimètres, Alimentations, Pinces, Analyseurs de Puissance, Sondes Haute-Tension…
Tension de 0,5 µV à 60 kV DC et 1 mV à 40 kV AC (prestation accréditée)
Intensité de 2 pA à 1 kA DC et 10 µA à 2 kA AC (prestation accréditée)
Puissance Mono et triphasé cos Entre 0,5 et 1 AR de 1 à 100 kW DC et de 0,75 W à 26 kW AC (prestation accréditée)
Résistance de 100 µΩ à 100 GΩ jusqu’à 1 kV en prestation accréditée et 15 kV en prestation non accréditée
Énergie Mono et triphasé cos Entre 0,5 et 1 AR, de 10 V à 230 V et de 0,1 A à 100 A (10 A en triphasé) (prestation accréditée)
Charge électrique : de 50 pC à 20 nC (prestation accréditée)
Calibrateurs de process en simulation électrique
Et aussi : Capacité, Inductance, Facteur de puissance, Compteur-Fréquencemètre,…
Thermo-Hygromètres…
Thermo-Hygromètres : de -70 °C à 180 °C de 5% à 95% HR
Masses normalisées ou non-normalisées
Prestations non accréditées : de 1 mg à 20 kg classe M1, M2, M3
Prestations accréditées : de 1 g à 20 kg classe M1, M2, et M3
Classe F2 : nous consulter
Thermo-Hygromètres, Pyromètres…
Sondes seules ou chaînes de mesure de mesure : de -80 °C à 1 200 °C (prestation accréditée)
Sondes de surface : 20 °C à 320 °C
Pyromètres : 100 °C à 900 °C
Thermo-Hygromètres : de -70 °C à 180 °C de 5% à 95% HR
Chaîne de température sur site de -80 °C à 1200 °C (Cofrac jusqu’à 600 °C)
Micropipettes, Pipettes, Burettes…
Mesures réalisées : de 1 µl à 500 ml à partir d’une contenance de 5 µl
Suivant NF EN ISO 8655
Enceintes Climatiques et Thermostatiques, Thermocycleurs, Étuves, Fours…
Enceintes climatiques & thermostatiques : de -80 °C à 1200 °C et de 1% à 95% HR
Caractérisation selon normes FDX 15-140 / L06-450
Qualification d’autoclaves : de 0 °C à 140 °C
Thermocycleurs PCR/QPCR