Expert calibration lab in
Lyon – France

Opening hours

Mon
08:00 - 17:00
Tue
08:00 - 17:00
Wed
08:00 - 17:00
Thu
08:00 - 17:00
Fri
08:00 - 16:00
Contact
+33 (0)4 37 42 33 06
7, rue de lombardie
69800 SAINT-PRIEST

ACCREDITATIONS

CAPABILITIES

Accredited Capabilities
Traceable Capabilities
Radiometry / Photometry
Pressure / Vacuum
Liquid flow
Gas flow
Torque
Force
Dimensional
Accelerometry
Chemical
Electricity
Humidity
Mass / Scale
Temperature
Volume
Thermal and climatic testing
Radiometry / Photometry

Radiometry / Photometry

Non-accredited Capabilities

Global Calibration Scope

  • Illuminance: 0.5 to 20 000 lux
  • Luminance: 0.2 to 15 000 ㏅/m2…

Common equipment serviced: Illuminance meter, Luminance meter, Spectrophotometer, Glossmeter, Photometer, Colorimeter, Pyranometer, Irradiance meter

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Pressure / Vacuum

Pressure / Vacuum

Non-accredited Capabilities

Global Calibration Scope

  • Vacuum: primary and secondary
  • Altimeter: up to 47 000 m
  • Pressure gauge: up to 500 MPa

Common equipment serviced: Manometers, Pressure calibrators, Sensor transmitters, Vacuum, Safety devices, Pressure balance

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Liquid flow

Liquid flow

Non-accredited Capabilities

Global Calibration Scope: Liquid flow (water): 0.12 l/h to 120 m3/h; Liquid flow (Hydrocarbon oils (Kerosene, Gas oil, Shell Tellus 32, Shell Tellus 100)): 0.6 l/min to 3000 l/min

Common equipment serviced: Liquid flow meter, Backflow gages, Flow analyzers, Gas flow meters, Flow transducers, Flow transmitters, Leak testers, Orifices, Rotameters, Turbine meters

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Gas flow

Gas flow

Non-accredited Capabilities

Global Calibration Scope: Gas flow (air): 0.5 ml/min to 4000 m3/h (the range is lower depending on gas used (nitrogen, argon or any inert gases)

Common equipment serviced: Anemometers (thermal & vane), Bubble flowmeters, Gas flow meters, Gas meters, Thermal mass flow controllers, Variable area flow meters, Backflow gages, Flow analyzers, Gas flow meters, Flow transducers, Flow transmitters, Leak testers, Orifices, Rotameters, Turbine meters

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Torque

Torque

Non-accredited Capabilities

Global Calibration Scope

  • Torque measuring devices (sensors, transducers, measuring chains…): 0,001 to 5 000 Nm
  • Hand torque tools (wrenches, screwdrivers …): 0,02 to 5 000 Nm
  • Torque multiplier: 50 to 5 000 Nm

Common equipment serviced: Torque analyzer, Torque sensor, Torque tester, Torquemeter, Torque transducer, Torque multiplier, Torque gun, Torque wrench, Torque screwdriver, Joint simulator, Hydraulic torque wrench

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Force

Force

Non-accredited Capabilities

Global Calibration Scope

  • Push pull force measuring devices in tension and compression: up to 1 MN
  • Force machine: up to 5 MN (compression) and up to 1 MN (tension)

Common equipment serviced: Dynamometers, Force machines (Tension and/or Compression), Load cell, Force gauges, Strainmeter, Crimping pliers, Charpy testers, Cable tie tools, Press, Retention tools, Wire wrap tools, Spring balance

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Dimensional

Dimensional

Non-accredited Capabilities

Global Calibration Scope

  • Gauge block (steel, tungsten carbide, ceramic…): up to 1500 mm
  • Long length (standard tape rules, peripheral gauges…): up to 100 m

Common equipment serviced: Angle instruments, Measuring bench/optical, Depth gauge, Gauge blocks, Height gauges, Micrometers, Length instruments, Limit gauges, Form and surface, Thread gauges

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Accelerometry

Accelerometry

Non-accredited Capabilities

Global Calibration Scope

  • Shock: between 20g and 5,000g (subject to device weight and voltage output)
  • Accelerometer: 0.1 m/s² to 750 m/s² (0.4 Hz to 10 kHz…)

Common equipment serviced: Integrated piezoelectric electronics, Piezoelectric accelerometers, Piezoresistive accelerometers, Charge amplifiers and systems

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Chemical

Chemical

Non-accredited Capabilities

Phmètres, Conductivimètres, Spectrophotomètres, Analyseurs divers, Incubateurs…
Mesures réalisées : pH, Conductivité, Viscosité, Densité, Osmolarité…
Analyseurs divers

Electricity

Electricity

Non-accredited Capabilities

Multimètres, Alimentations, Pinces, Analyseurs de Puissance, Sondes Haute-Tension…
Tension de 0,5 µV à 60 kV DC et 1 mV à 40 kV AC (prestation accréditée)
Intensité de 2 pA à 1 kA DC et 10 µA à 2 kA AC (prestation accréditée)
Puissance Mono et triphasé cos  Entre 0,5 et 1 AR de 1 à 100 kW DC et de 0,75 W à 26 kW AC (prestation accréditée)
Résistance de 100 µΩ à 100 GΩ jusqu’à 1 kV en prestation accréditée et 15 kV en prestation non accréditée
Énergie Mono et triphasé cos  Entre 0,5 et 1 AR, de 10 V à 230 V et de 0,1 A à 100 A (10 A en triphasé) (prestation accréditée)
Charge électrique : de 50 pC à 20 nC (prestation accréditée)
Calibrateurs de process en simulation électrique
Et aussi : Capacité, Inductance, Facteur de puissance, Compteur-Fréquencemètre,…

Humidity

Humidity

Non-accredited Capabilities

Thermo-Hygromètres…

Thermo-Hygromètres : de -70 °C à 180 °C de 5% à 95% HR

 

Mass / Scale

Mass / Scale

Accredited Capabilities

Masses normalisées ou non-normalisées

Prestations non accréditées : de 1 mg à 20 kg classe M1, M2, M3

Prestations accréditées : de 1 g à 20 kg classe M1, M2, et M3
Classe F2 : nous consulter

Temperature

Temperature

Non-accredited Capabilities

Thermo-Hygromètres, Pyromètres…
Sondes seules ou chaînes de mesure de mesure : de -80 °C à 1 200 °C (prestation accréditée)
Sondes de surface : 20 °C à 320 °C
Pyromètres : 100 °C à 900 °C
Thermo-Hygromètres : de -70 °C à 180 °C de 5% à 95% HR
Chaîne de température sur site de -80 °C à 1200 °C (Cofrac jusqu’à 600 °C)

Volume

Volume

Non-accredited Capabilities

Micropipettes, Pipettes, Burettes…
Mesures réalisées : de 1 µl à 500 ml à partir d’une contenance de 5 µl
Suivant NF EN ISO 8655

Thermal and climatic testing

Thermal and climatic testing

Non-accredited Capabilities

Enceintes Climatiques et Thermostatiques, Thermocycleurs, Étuves, Fours…
Enceintes climatiques & thermostatiques : de -80 °C à 1200 °C et de 1% à 95% HR
Caractérisation selon normes FDX 15-140 / L06-450
Qualification d’autoclaves : de 0 °C à 140 °C
Thermocycleurs PCR/QPCR

Radiometry / Photometry
Pressure / Vacuum
Liquid flow
Gas flow
Torque
Force
Dimensional
Accelerometry
Chemical

Phmètres, Conductivimètres, Spectrophotomètres, Analyseurs divers, Incubateurs…
Mesures réalisées : pH, Conductivité, Viscosité, Densité, Osmolarité…
Analyseurs divers

Electricity

Multimètres, Alimentations, Pinces, Analyseurs de Puissance, Sondes Haute-Tension…
Tension de 0,5 µV à 60 kV DC et 1 mV à 40 kV AC (prestation accréditée)
Intensité de 2 pA à 1 kA DC et 10 µA à 2 kA AC (prestation accréditée)
Puissance Mono et triphasé cos  Entre 0,5 et 1 AR de 1 à 100 kW DC et de 0,75 W à 26 kW AC (prestation accréditée)
Résistance de 100 µΩ à 100 GΩ jusqu’à 1 kV en prestation accréditée et 15 kV en prestation non accréditée
Énergie Mono et triphasé cos  Entre 0,5 et 1 AR, de 10 V à 230 V et de 0,1 A à 100 A (10 A en triphasé) (prestation accréditée)
Charge électrique : de 50 pC à 20 nC (prestation accréditée)
Calibrateurs de process en simulation électrique
Et aussi : Capacité, Inductance, Facteur de puissance, Compteur-Fréquencemètre,…

Humidity

Thermo-Hygromètres…

Thermo-Hygromètres : de -70 °C à 180 °C de 5% à 95% HR

 

Mass / Scale

Masses normalisées ou non-normalisées

Prestations non accréditées : de 1 mg à 20 kg classe M1, M2, M3

Prestations accréditées : de 1 g à 20 kg classe M1, M2, et M3
Classe F2 : nous consulter

Temperature

Thermo-Hygromètres, Pyromètres…
Sondes seules ou chaînes de mesure de mesure : de -80 °C à 1 200 °C (prestation accréditée)
Sondes de surface : 20 °C à 320 °C
Pyromètres : 100 °C à 900 °C
Thermo-Hygromètres : de -70 °C à 180 °C de 5% à 95% HR
Chaîne de température sur site de -80 °C à 1200 °C (Cofrac jusqu’à 600 °C)

Volume

Micropipettes, Pipettes, Burettes…
Mesures réalisées : de 1 µl à 500 ml à partir d’une contenance de 5 µl
Suivant NF EN ISO 8655

Thermal and climatic testing

Enceintes Climatiques et Thermostatiques, Thermocycleurs, Étuves, Fours…
Enceintes climatiques & thermostatiques : de -80 °C à 1200 °C et de 1% à 95% HR
Caractérisation selon normes FDX 15-140 / L06-450
Qualification d’autoclaves : de 0 °C à 140 °C
Thermocycleurs PCR/QPCR

Laboratory tour

Our laboratories provides instrument calibration and repair services that are accredited and/or certified in accordance with ISO/IEC 17025. Instrument calibration and repair services can be delivered at your site or at our lab.