CAPABILITIES
Volume
Global Calibration Scope
- Volumetric Instruments (Beakers, Volumetric Containers…): up to 20 000 mL
- Pipette: 0.1µL up to 1 000 mL
- Syringe: up to 200 mL
Common equipment serviced: Burettes, Flask, Syringe, Pipettes, Test tubes, Beakers, Dispenser, Tanks, Vessels, Gauge overflow, Gauge windows, Concrete air content meters, Level probes Pycnometers, Titrators
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Radiometry / Photometry
Global Calibration Scope
- Illuminance: 0.5 to 20 000 lux
- Luminance: 0.2 to 15 000 ㏅/m2…
Common equipment serviced: Illuminance meter, Luminance meter, Spectrophotometer, Glossmeter, Photometer, Colorimeter, Pyranometer, Irradiance meter
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Liquid flow
Global Calibration Scope: Liquid flow (water): 0.12 l/h to 120 m3/h; Liquid flow (Hydrocarbon oils (Kerosene, Gas oil, Shell Tellus 32, Shell Tellus 100)): 0.6 l/min to 3000 l/min
Common equipment serviced: Liquid flow meter, Backflow gages, Flow analyzers, Gas flow meters, Flow transducers, Flow transmitters, Leak testers, Orifices, Rotameters, Turbine meters
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Gas flow
Global Calibration Scope: Gas flow (air): 0.5 ml/min to 4000 m3/h (the range is lower depending on gas used (nitrogen, argon or any inert gases)
Common equipment serviced: Anemometers (thermal & vane), Bubble flowmeters, Gas flow meters, Gas meters, Thermal mass flow controllers, Variable area flow meters, Backflow gages, Flow analyzers, Gas flow meters, Flow transducers, Flow transmitters, Leak testers, Orifices, Rotameters, Turbine meters
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Accelerometry
Global Calibration Scope
- Frequency Response: 0.5 to 15 kHz,
- Amplitude Response: 1-1000 (Centrifugal acceleration)
- Sensitivity (1 to 20) g
Common equipment serviced: Accelerometers, Vibration Generators, Impact Hammers
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Acoustics
Global Calibration Scope
- 64-114 dB& 1kHz (124 db @ 250Hz) 100 Hz – 16 kHz
- Microphones Frequency Response: 20 Hz – 20 kHz
Common equipment serviced: Microphone, Calibrator, Sound level meter, Pistonphone
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Chemical
Global Calibration Scope
- Standard solutions
Common equipment serviced: pH meters, Conductivity meters
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Electricity
Global Calibration Scope
- DC/Low Frequency: Voltage generation up to 40 kV DC and 20 kV AC; voltage measurement up to 100 kV DC and 70 kV AC
- Electrical temperature simulation: Pt 100, TC
- Current up to 1000 A DC and 100 A @ 20 Hz to 100kHz
Common equipment serviced: Electrical-DC/Low Frequency: Multimeters, Calibrators, RLC Bridges, Oscilloscopes, Probes, Power Supplies, Electronic Loads, Shunts, Capacitors, Inductors, Megohmmeters, Sensors, Frequency Counters, etc.
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Force
Global Calibration Scope
- Compression & Tension: 50 – 50,000 lbfUp to 1,500 lbf with deadweight
Common equipment serviced: Load Cells, Force Gages, Dynamometers
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Humidity
Global Calibration Scope
- 10 to 95% HR from 5 °C to 70 °C with humidity generator
Common equipment serviced: RH Meters, Probes, Psychrometers, etc.
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Pressure / Vacuum
Global Calibration Scope
- Absolute – relative – differential pressure: gas up to 1000 PSI / water & oil up to 12 000 PSI
Common equipment serviced: Calibrators, Digital pressure gauges, Sensors/Transmitters, etc.
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Temperature
Global Calibration Scope
- -40 °C to 660 °C with Drywells,
- -15 °C to 500 °C with black body, on-site tests in oven and chambers
Common equipment serviced: TC Probes, RTD, Drywells, Calibration Baths, Calibrators, IR Meters, Chambers and Ovens…
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Torque
Global Calibration Scope
- From 2 ozf⸱in to 5000 lbf⸱ft
Common equipment serviced: Torque transducers, Torque calibrators, Torque tools
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Dimensional
Global Calibration Scope
- Rotary encoders: -up to 360°, cmc 4.7 arc sec
- Gauge blocks: -up to 20”
- Ring gauges and plugs: -up to 12”
- Length standards: -up to 48”
Common equipment serviced: Gage Blocks, Surface Plates, Ring Gages, Pin Gages, Threaded Plug Gages, Angle Encoders, Thread Rings
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Mass / Scale
Global Calibration Scope
- Mass 1 mg to 32 kg Class 4,
- Scales up to 1500 lbf
Common equipment serviced: Mass, Balances, Floor Scales, Durometers, ect.
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Time / Frequency
Global Calibration Scope
- Timometer
- GPS system
- Tachometer: -up to 100000 RPM- optical
Common equipment serviced: Timers, Frequency counters, Stop watches, Tachometers
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Global Calibration Scope
- Frequency Response: 0.5 to 15 kHz,
- Amplitude Response: 1-1000 (Centrifugal acceleration)
- Sensitivity (1 to 20) g
Common equipment serviced: Accelerometers, Vibration Generators, Impact Hammers
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Global Calibration Scope
- 64-114 dB& 1kHz (124 db @ 250Hz) 100 Hz – 16 kHz
- Microphones Frequency Response: 20 Hz – 20 kHz
Common equipment serviced: Microphone, Calibrator, Sound level meter, Pistonphone
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Global Calibration Scope
- Standard solutions
Common equipment serviced: pH meters, Conductivity meters
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Global Calibration Scope
- DC/Low Frequency: Voltage generation up to 40 kV DC and 20 kV AC; voltage measurement up to 100 kV DC and 70 kV AC
- Electrical temperature simulation: Pt 100, TC
- Current up to 1000 A DC and 100 A @ 20 Hz to 100kHz
Common equipment serviced: Electrical-DC/Low Frequency: Multimeters, Calibrators, RLC Bridges, Oscilloscopes, Probes, Power Supplies, Electronic Loads, Shunts, Capacitors, Inductors, Megohmmeters, Sensors, Frequency Counters, etc.
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Global Calibration Scope
- Compression & Tension: 50 – 50,000 lbfUp to 1,500 lbf with deadweight
Common equipment serviced: Load Cells, Force Gages, Dynamometers
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Global Calibration Scope
- 10 to 95% HR from 5 °C to 70 °C with humidity generator
Common equipment serviced: RH Meters, Probes, Psychrometers, etc.
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Global Calibration Scope
- Absolute – relative – differential pressure: gas up to 1000 PSI / water & oil up to 12 000 PSI
Common equipment serviced: Calibrators, Digital pressure gauges, Sensors/Transmitters, etc.
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Global Calibration Scope
- -40 °C to 660 °C with Drywells,
- -15 °C to 500 °C with black body, on-site tests in oven and chambers
Common equipment serviced: TC Probes, RTD, Drywells, Calibration Baths, Calibrators, IR Meters, Chambers and Ovens…
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Global Calibration Scope
- From 2 ozf⸱in to 5000 lbf⸱ft
Common equipment serviced: Torque transducers, Torque calibrators, Torque tools
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Global Calibration Scope
- Rotary encoders: -up to 360°, cmc 4.7 arc sec
- Gauge blocks: -up to 20”
- Ring gauges and plugs: -up to 12”
- Length standards: -up to 48”
Common equipment serviced: Gage Blocks, Surface Plates, Ring Gages, Pin Gages, Threaded Plug Gages, Angle Encoders, Thread Rings
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Global Calibration Scope
- Mass 1 mg to 32 kg Class 4,
- Scales up to 1500 lbf
Common equipment serviced: Mass, Balances, Floor Scales, Durometers, ect.
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Global Calibration Scope
- Timometer
- GPS system
- Tachometer: -up to 100000 RPM- optical
Common equipment serviced: Timers, Frequency counters, Stop watches, Tachometers
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.