Expert calibration lab in
Toulon – France

Opening hours

Mon
08:00 - 05:00
Tue
08:00 - 17:00
Wed
08:00 - 17:00
Thu
08:00 - 17:00
Fri
08:00 - 16:00
Contact
+33 (0)4 94 13 54 80
875 avenue Léon Amic
83390 CUERS

ACCREDITATIONS

CAPABILITIES

Accredited Capabilities
Traceable Capabilities
Liquid flow
Gas flow
Force
Dimensional
Radiometry / Photometry
3D Measurement
Accelerometry
Chemical
Electricity
Mass / Scale
Pressure / Vacuum
Temperature
Thermal and climatic testing
Liquid flow

Liquid flow

Non-accredited Capabilities

Global Calibration Scope: Liquid flow (water): 0.12 l/h to 120 m3/h; Liquid flow (Hydrocarbon oils (Kerosene, Gas oil, Shell Tellus 32, Shell Tellus 100)): 0.6 l/min to 3000 l/min

Common equipment serviced: Liquid flow meter, Backflow gages, Flow analyzers, Gas flow meters, Flow transducers, Flow transmitters, Leak testers, Orifices, Rotameters, Turbine meters

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Gas flow

Gas flow

Non-accredited Capabilities

Global Calibration Scope: Gas flow (air): 0.5 ml/min to 4000 m3/h (the range is lower depending on gas used (nitrogen, argon or any inert gases)

Common equipment serviced: Anemometers (thermal & vane), Bubble flowmeters, Gas flow meters, Gas meters, Thermal mass flow controllers, Variable area flow meters, Backflow gages, Flow analyzers, Gas flow meters, Flow transducers, Flow transmitters, Leak testers, Orifices, Rotameters, Turbine meters

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Force

Force

Non-accredited Capabilities

Global Calibration Scope

  • Push pull force measuring devices in tension and compression: up to 1 MN
  • Force machine: up to 5 MN (compression) and up to 1 MN (tension)

Common equipment serviced: Dynamometers, Force machines (Tension and/or Compression), Load cell, Force gauges, Strainmeter, Crimping pliers, Charpy testers, Cable tie tools, Press, Retention tools, Wire wrap tools, Spring balance

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Dimensional

Dimensional

Non-accredited Capabilities

Global Calibration Scope

  • Gauge block (steel, tungsten carbide, ceramic…): up to 1500 mm
  • Long length (standard tape rules, peripheral gauges…): up to 100 m

Common equipment serviced: Angle instruments, Measuring bench/optical, Depth gauge, Gauge blocks, Height gauges, Micrometers, Length instruments, Limit gauges, Form and surface, Thread gauges

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Radiometry / Photometry

Radiometry / Photometry

Non-accredited Capabilities

Global Calibration Scope

  • Illuminance: 0.5 to 20 000 lux
  • Luminance: 0.2 to 15 000 ㏅/m2…

Common equipment serviced: Illuminance meter, Luminance meter, Spectrophotometer, Glossmeter, Photometer, Colorimeter, Pyranometer, Irradiance meter

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

3D Measurement

3D Measurement

Non-accredited Capabilities

Mesures 3D Laboratoire : Avec contact (MMT) et sans contact (MMT optique)
Pièces mécaniques diverses (toutes tailles, tous matériaux…)
Gabarits & calibres sur plans
Comparaison avec CAO

Mesure 3D Site : Laser Traker, Bras de mesures poly-articulé, Scanning
Outillages de production
Machine-outils
Pièces mécaniques
Comparaison avec CAO

 

Accelerometry

Accelerometry

Non-accredited Capabilities

Accéléromètres (piézoélectrique, charge, capacitif, piézorésistif), Vélocimètres, Générateurs de vibrations, Mesureurs de vibrations (seuls ou en chaîne), Amplificateurs, Conditionneurs, Convertisseurs, Enregistreurs d’événements…
Mesures réalisées : sensibilité, vitesse, accélération, déplacement, fréquence de résonance
Plages de mesure : réponse en fréquence (amplitude et phase) de 0,6 Hz à 20 kHz et recherche de la fréquence de résonance jusqu’à 50 kHz
Mise à jour des capteurs TEDs

 

Chemical

Chemical

Non-accredited Capabilities

Détecteurs de gaz O2 , NH3 , 4 Gaz, Stations Test BW…
Vérification selon procédure constructeur (agrément BW) + Maintenance Préventive + Réparation
Détecteurs concernés : BW, MSA, DRÄGER, INDUSTRIAL SCIENTIFIQUE

Comptage particulaire optique : Surveillance d’atmosphère (salles blanches), Applications diverses (compteur portatif), Exemples d’instruments : MET ONE 3425, TSI 7501A2F, BECKMAN 6005…
Vérification du débit d’air
Étalonnage de l’efficacité de comptage
Étalonnage de la granulométrie

Phmètres, Conductivimètres

Electricity

Electricity

Non-accredited Capabilities

Analyseurs de Spectre, Générateurs, Synthétiseurs de fréquence, Analyseurs de réseaux vectoriels & scalaires, Analyseurs & générateurs de modulations numériques (IQ), Fréquencemètres, Wattmètres, Sondes de puissance, Milliwattmètres…
Gamme fréquence : DC – 50 GHz
Modulation IQ – Bruit de phase
Puissance jusqu’à 150 W

Mesureurs et détecteurs de champs électromagnétiques…
Mesures réalisées : champs électriques (E-Field) et champs électromagnétiques (H-Field)
Gamme fréquence : DC – 1 GHz

 

Mass / Scale

Mass / Scale

Non-accredited Capabilities

Global Calibration Scope

  • Mass: 1 mg to 1000 kg (range depending to class less than E2, F2, M1…)
  • Scale: 1mg to 200 000 kg with weights class from E2, F1 to M1-2
  • Legal metrology: maintenance and repair for scales up to 180 000 kg

Common equipment serviced: Weight, Weighing devices (Weighing scale, Hopper scale, Tank scale, Platform scale, etc), Weighing instruments for blood collection bags

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Pressure / Vacuum

Pressure / Vacuum

Non-accredited Capabilities

Global Calibration Scope

  • Vacuum: primary and secondary
  • Altimeter: up to 47 000 m
  • Pressure gauge: up to 500 MPa

Common equipment serviced: Manometers, Pressure calibrators, Sensor transmitters, Vacuum, Safety devices, Pressure balance

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Temperature

Temperature

Non-accredited Capabilities

Thermo-Hygromètres, Enceintes climatiques, Étuves, Fours, Incubateurs CO2 , Chambres Froides, Frigos, Autoclaves, Pyromètres…
Contrôles de fuites circuit réfrigérant
Plage de mesures : -200 ˚C à 1 400 ˚C

Thermal and climatic testing

Thermal and climatic testing

Accredited Capabilities

Thermo-Hygromètres, Enceintes climatiques, Étuves, Fours, Incubateurs CO2 , Chambres Froides, Frigos, Autoclaves, Pyromètres…
Caractérisation selon normes : FD X15-140, CEI 60068-3, AMS 2750, NFL 06-450

Liquid flow
Gas flow
Force
Dimensional
Radiometry / Photometry
3D Measurement

Mesures 3D Laboratoire : Avec contact (MMT) et sans contact (MMT optique)
Pièces mécaniques diverses (toutes tailles, tous matériaux…)
Gabarits & calibres sur plans
Comparaison avec CAO

Mesure 3D Site : Laser Traker, Bras de mesures poly-articulé, Scanning
Outillages de production
Machine-outils
Pièces mécaniques
Comparaison avec CAO

 

Accelerometry

Accéléromètres (piézoélectrique, charge, capacitif, piézorésistif), Vélocimètres, Générateurs de vibrations, Mesureurs de vibrations (seuls ou en chaîne), Amplificateurs, Conditionneurs, Convertisseurs, Enregistreurs d’événements…
Mesures réalisées : sensibilité, vitesse, accélération, déplacement, fréquence de résonance
Plages de mesure : réponse en fréquence (amplitude et phase) de 0,6 Hz à 20 kHz et recherche de la fréquence de résonance jusqu’à 50 kHz
Mise à jour des capteurs TEDs

 

Chemical

Détecteurs de gaz O2 , NH3 , 4 Gaz, Stations Test BW…
Vérification selon procédure constructeur (agrément BW) + Maintenance Préventive + Réparation
Détecteurs concernés : BW, MSA, DRÄGER, INDUSTRIAL SCIENTIFIQUE

Comptage particulaire optique : Surveillance d’atmosphère (salles blanches), Applications diverses (compteur portatif), Exemples d’instruments : MET ONE 3425, TSI 7501A2F, BECKMAN 6005…
Vérification du débit d’air
Étalonnage de l’efficacité de comptage
Étalonnage de la granulométrie

Phmètres, Conductivimètres

Electricity

Analyseurs de Spectre, Générateurs, Synthétiseurs de fréquence, Analyseurs de réseaux vectoriels & scalaires, Analyseurs & générateurs de modulations numériques (IQ), Fréquencemètres, Wattmètres, Sondes de puissance, Milliwattmètres…
Gamme fréquence : DC – 50 GHz
Modulation IQ – Bruit de phase
Puissance jusqu’à 150 W

Mesureurs et détecteurs de champs électromagnétiques…
Mesures réalisées : champs électriques (E-Field) et champs électromagnétiques (H-Field)
Gamme fréquence : DC – 1 GHz

 

Mass / Scale
Pressure / Vacuum
Temperature

Thermo-Hygromètres, Enceintes climatiques, Étuves, Fours, Incubateurs CO2 , Chambres Froides, Frigos, Autoclaves, Pyromètres…
Contrôles de fuites circuit réfrigérant
Plage de mesures : -200 ˚C à 1 400 ˚C

Thermal and climatic testing

Thermo-Hygromètres, Enceintes climatiques, Étuves, Fours, Incubateurs CO2 , Chambres Froides, Frigos, Autoclaves, Pyromètres…
Caractérisation selon normes : FD X15-140, CEI 60068-3, AMS 2750, NFL 06-450

Réparation mécanique et électronique de sous-ensembles et équipements de mesures, de cartes électroniques et de systèmes industriels…
Réparation au composant,
Traitement de l’obsolescence ciblée,
Recherche d’équivalence fonctionnelle et au niveau composant,
Partenariat constructeur,
Réfection de pistes et PCB brûlés…

Contrôle Non-Destructif (CND)
Détecteurs de défauts par courant de Foucault ou par ultrasons (exemples instruments : Phasec, Elotest, USN, Nortec…)
Mesures réalisées : vérification de la partie électrique selon les différentes normes (NF EN ISO 15548-1 et NF EN 12668-1)

Contrôle Non-Destructif (CND) Rayons X
Générateur Rayons X 150kV
Agrandissement jusqu’à 250 fois
Charge admissible : 100 kg
Dimensions pièces admissibles: L 600 x l 600 x h 720 mm
Pénétration acier : 10 mm
Pénétration aluminium : 100 mm
Rotation : 4 axes dont 1 axe à 360°

INGÉNIERIE :
Électronique, Mécanique, Instrumentation et Réalisation de moyens de mesures, Bancs de test, Racks de sécurisation…
Développement complet de bancs de test
Étude, réalisation et câblage de racks électriques
Étude et développement d’outils spécifiques liés à la mesure de systèmes industriels

MAINTENANCE DES SYSTÈMES DE PRODUCTION
Maintenance préventive et curative de Station D’essais industriels, Échangeurs thermiques, Coffrets de pilotage et d’acquisition, Cartes électroniques…
Maintenance préventive de systèmes électriques, mécaniques, hydrauliques, pneumatiques
Rénovation de systèmes d’information de mesure et de pilotage

 

Laboratory tour

Our laboratories provides instrument calibration and repair services that are accredited and/or certified in accordance with ISO/IEC 17025. Instrument calibration and repair services can be delivered at your site or at our lab.
Secret Link